MTP / MPO CABLE & CASSETTES

In this category we offer custom MTP trunk assemblies, MTP fanout assemblies, and MTP cassettes in multimode om3 and om4, and singlemode. We offer these assemblies in the following jacket types: indoor plenum, indoor/outdoor plenum rated, outdoor (OSP) loose tube, and outdoor armored direct burial rated. We also offer both our MTP trunk assemblies and MTP fanout assemblies with microarmor jacket. All of our MTP trunk and fanout assemblies are custom made to order is the usa and include corning glass and genuine us conec connectors. Our manufacturing process includes strict quality control and come fully tested with a test report. Our MTP cassettes are premium quality and include low loss and genuine us conec connectors. We also offer high density MPO cassettes for high strand count installations that require minimal rack space.

Show More
Overview

MTP/MPO Cable Polarity

Optical fiber networks require two fibers to make a complete circuit. The matching of the transmit Tx signal to the receive Rx equipment is referred to as polarity, and a transmit and receive side on optical transceivers usually use a duplex fiber connector to maintain the polarity. On most cabling systems, maintaining polarity just requires that the A side of one connector pair matches the B side of the other connector pair, with fiber connectors such as ST, LC, SC, and MTRJ.

MTP/MPO high density network design requires its own set of rules regarding maintaining polarity throughout the link. These three polarity methods are commonly referred to as Method A, Method B, and Method C, and we will discuss the difference further here. Come see why our MTP & MPO cables, cassettes, and components are second to none in the industry. 


Method A – Straight Through

This type of MTP cable has a key up key down position, and the fiber remains the same straight through the cable. Therefore, each fiber is in the same position on each end of the cable. Fiber 1 in the cassette mates to Fiber 1 in the cable assembly, which mates to Fiber 1 in the end cassette. This type of MTP cable has a key up key down position, and the fiber remains the same straight through the cable. Therefore, each fiber is in the same position on each end of the cable. Fiber 1 in the cassette mates to Fiber 1 in the cable assembly, which mates to Fiber 1 in the end cassette.

The transmit/receive flip must happen with the patch cords either at the beginning or end of the link to ensure proper transceiver polarity.


Method B – Fully Flipped (1-12, 12-1)

This method utilizes a key up to key up position and this fiber cable is fully flipped on either end. This type of mating creates an inversion, where Fiber 1 is mated with Fiber 12, and Fiber 2 is mated with Fiber 11, etc. For these cables to preform properly, one of the cassettes would need to be inverted internally for Fiber 12 is mated with Fiber 1 at the end of the link. This method requires two different cassettes with special labeling to identify which one is flipped. This circuit is completed with using straight patch cords at the beginning and end of the link.

*Note- method B is not compatible with our standard QuickTrex cassettes.


Method C – Pair Flip

Method C and Method A are very similar, with the main difference being the flipping of the patch cords in the link. This method uses key up key down, and the polarity flip takes place within the cable itself. Each adjacent pairs of fiber at one end are flipped at the other end. So, Fiber 1 and Fiber 2 becomes Fiber 2 and Fiber 1 at the other end, and so on.

This circuit is completed by using straight patch cords at the beginning and end of the link.


MTP/MPO Connector Types

Although most people in the industry refer to this connector as MTP, it is actually correct to also call it MPO. The term MTP is a registered trademark of USConec and identifies their specific brand of the MPO-style connector.

The name MPO stands for Multifiber Push On, and typically consists of a 12 strand Ribbon Fiber that is terminated to a single compact push on connector. Our MTP & MPO cables, cassettes, components and connector types are available online now.


Male MTP/MTO Connector

The pins on the MTP/MPO connector signifies that is it a Male connector.

The white dot on the right, signifies position 1 on the MTP pinout.

The raised tab on the top of the connector signifies it is in the key up position.


Female MTP/MTO Connector

The lack of pins on the MTP/MPO connector signifies that it is a Female connector.

The white dot on the right, signifies position 1 on the MTP pinout.

The raised tab on the top of the connector signifies it is in the key up position.


MTP Strand Counts

There are three popular MTP strand counts available on the market today.

The MTP 8 Connector utilizes 8 of the 12 fibers in a standard 12 Fiber Connector. QSFP applications use the outer four fiber spots (1 – 4 and 8-12) of the MTP connector with four fibers used to transmit and four to receive. Method B is the most commonly used polarity method for a MTP 8.

The MTP 12 Connector is the most popular choice for a MTP connector and is recognized as industry standard. Method A, B, and C are available in a MTP 12. Method A is the recommended polarity method.

The MTP 24 is the most cost effective and high-density solution for MTP, as this connector is able to harness 24 fiber strands in one connector. There are various polarity options for MTP 24, but Method A is recommended, and is standard on our QuickTreX assemblies.


Connecting MTP Connectors

When connecting, or mating, two MTP connectors together, you will need an MTP adapter to accomplish this. The male connector should be in the key up position, and the female in the key down position.


MTP Cassettes

Maintaining proper polarity across your network is also applicable when choosing a cassette. Cassettes come in a few different forms: 12 Fiber (1 x 12), 24 Fiber (2 x 12), and 24 Fiber (1 x 24). It is especially important to make sure the MTP configuration on your MTP Trunk Assembly or MTP Fanout Assembly is compatible with the MTP Cassette you choose.

Cassettes will be labeled as Method A/C or Method B. The main difference here is orientation of the way the MTP cables are mated together. Alignment pins are pre-installed in the MTP/MPO connector located inside the cassette. These pins precisely align the mating fibers in the MTP/MPO connectors at either end of the cables that plug into the cassettes.


For Method A or Method C Polarity:

Method-A cassettes make a key up to key down connection between the internal MTP connector and the MTP cable connector.

The cassettes will already be in a key up position, and when plugging in your MTP connector it needs to be in the key down position.


For Method B Polarity:

Method-B cassettes make a key up to key up, key down to key down connection. For these cables to perform properly, one of the cassettes would need to be inverted internally for Fiber 12 is mated with Fiber 1 at the end of the link. This method requires two different cassettes with special labeling to identify which one is flipped.

One cassette will be in the key up position, with the MTP cable also being key up.

One cassette will be in the key down position, with the MTP cable also being key down.

Method B cassettes are not recommended for Singlemode APC fiber applications, because the angles of the mating connectors do not line up properly with this configuration and are not sufficient for low loss applications.

*QuickTreX cassettes support a method A/C configuration, and are not compatible with Method B.


Method B in Parallel Optics

Method B polarity is particularly useful in regard to 40G parallel optic applications, and direct switch to switch connectivity. Method B MTP cables are also referred to as a QSFP/QSFP+ cable or direct attach 40GBASE-SR4, 40GBASE-PLR4 or 40GBASE-PLRL4. This orientation is useful because instead of an alternating Tx to Rx duplex pattern, 40G parallel optics utilizes the flipped Pin 1 to Pin 12, Pin 12 to Pin 1 pinout.

Female to Female type B trunk cables can also be used for a direct switch to switch connectivity going directly into 40G transceivers, or with an MTP adapter, used to connect a patch panel to a QSFP+ transceiver.


Completing the Link

We have talked about the different types of MTP polarities, and how to properly mate two MTP connectors. The last step in a standard MTP application is breaking out the high-density fiber strands into standard fiber connectors.

If you are using a cassette, then you will need standard fiber jumper cables to complete the polarity methodology. If you are using an adapter, then you will be connecting the MTP trunk cable to an MTP Fanout Assembly which will have standard fiber connector fanouts. The MTP Fanout Builder will go into more depth on configuration there, so let’s focus on a MTP cassette method with patch cables.


There are two types of duplex fiber patch cables as defined in the TIA standard: A to A, and A to B. Maintaining proper polarity requires the B Tx signal to connect to the A Rx signal.

A to B patch cables are also known as “straight-through”

A to A patch cables are also known as “flipped”

Patch cords made with individual single fiber connectors at each end allow the flexibility for connections to be “swapped” when a polarity reversal is required. Our QuickTreX Custom USA fiber optic patch cables will provide the ability to be swapped.


MTP Accessories


There are a variety of hardware accessories that go along with most MTP/MTO installations. It's important to match what you need with what you have for maximum performance and full compatibility.

MTP Coupler

An MTP coupler is used to connect two 12 fiber MTP male to MTP female connectors together.

MTP Adapter Panel

This can also be accomplished using an MTP adapter panel which will have 6 or 8 MTP/MTO couplers within the panel. This is useful to connect an MTP assembly with an MTP Fanout cable - Male to Female Connections

MTP Cassette

A cassette will have an MTP connector in the back which will be a male connector. Therefore, MTP cables that plug into the cassettes will be a female cable.

MTP Cabling and Fanouts


Matching your MTP trunk assembly to the appropriate fanout cabling situation isn't always simple. Here are some of the choices for what you might need to match with what you have for maximum performance and full compatibility.

Pulling Eyes

A pulling eye is designed to be attached to a pull string that runs the full length of your conduit. Your assembly is then pulled through the conduit via the pull string. It can also be used to pull your assembly through duct work, in wall cavities, or other areas where routing needs to take place. Our pulling eyes include a heavy-duty swivel hook to prevent the cable from twisting during the pull. The metal pull hook is attached to a designated pull string inside of your assembly usually consisting of Kevlar so that you are not pulling on the fiber strands themselves. The pulling eye includes heat shrink tubing that covers the back side of the pull hook, and the pull basket that contains your fiber optic connectors.

The pull basket is constructed with super strong polyethylene mesh that tightens itself around the strands and connectors keeping them securely in place during install. The connectors are also staggered inside of the pull basket for less bulk, and each connector is individually plastic wrapped to prevent contamination by pulling lubricants and other debris. Our pulling eyes are always recommended as they make your pull much easier while providing further protection of your connectors.

Chassis Types

There are three popular MTP strand counts available on the market today.

These MTP®/MPO cassettes will fit most standard LGX Fiber Optic Enclosures that include enough depth to accommodate the MTP assembly in the back of it.
Note: All LGX rack mount enclosures are compatible and 2-12 panel LGX wall mount enclosures are compatible

These MPO cassettes will only fit SHD fiber optic enclosures and are great for high strand count installs typically seen in data centers, campuses, and other commercial settings. Note: SHD enclosures are only available in rack mount style. We offer a 5 panel (1U) and 14 panel (2U).

Strands

When selecting the “strand” count on the MTP Cassette Configurator, it is important to match the MTP/MPO connector type with the correct cassette.

For instance, if you are ordering a 1x 24 MTP Assembly, then that cable would not be compatible with a 2 x 12 MTP cassette. Both examples utilize 24 fibers but are wired differently.

A single 24 fiber MTP connector will specifically require an MTP Cassette that accepts 1 x 24. An assembly that has 2 x 12 MTP connectors, would need a cassette that accepts two 12 fiber MTP connectors.

Superior Customer Service // Free Technical Support // Fast Lead Times

videos

LANShack Pre-Terminated Fiber Optic Assemblies tom damiano discussing pre-terminated fiber optic assemblies
Custom MTP Cable Assemblies and Cassettes tom damiano discussing mtp cable assemblies
How to Fusion Splice Fiber Optic Cable video tutorial how to fusion splice two fiber optic cables together