What is an MTP trunk cable?
An MTP trunk cable is a high-performance fiber optic cable designed to support high-density data transmission in modern networking environments.
These fiber optic cables serve as a backbone for data centers, high-speed enterprise networks, and telecommunications systems, enabling seamless and efficient communication between devices and network infrastructure.
The primary function of an MTP trunk cable is to consolidate multiple fiber strands into a single, compact, and easy-to-manage connection, reducing cable clutter and improving scalability in complex network setups.
These cables typically come in 12, 24, 48, or higher fiber counts, allowing for rapid deployment of 10G, 40G, 100G, 200G, and even 400G network solutions without requiring multiple individual fiber patch cords.
Functions of MTP Trunk Cables in Data Centers
MTP trunk cables work by using MTP (Multifiber Termination Push-on) connectors, which feature precision alignment pins and an advanced push-pull mechanism for quick and reliable connections.
Unlike traditional fiber optic connectors, MTP connectors are engineered with low insertion loss and high return loss, ensuring optimal signal integrity and minimal data loss over long distances.
These cables are available in different polarity types (A, B, and C) to support various network configurations and maintain proper signal alignment. Their plug-and-play nature significantly reduces installation time, making them an ideal choice for large-scale deployments.
Features of MTP Trunk Cables
When it comes to reliability, MTP trunk cables are built for durability and long-term performance. They are manufactured using premium-grade fiber optics and feature robust outer jackets that protect against environmental factors like dust, moisture, and mechanical stress. Their low maintenance requirements, high-density design, and minimal signal attenuation make them a preferred choice for mission-critical applications where network uptime and data integrity are essential. Moreover, MTP connectors are engineered with removable housings, allowing for easy cleaning and re-polishing to maintain performance over time.
Usage of MTP Trunk Cables
The usage of MTP trunk cables spans across various industries and applications. They are commonly deployed in data centers to connect core networking equipment such as switches, routers, and servers, facilitating high-bandwidth communication. In telecommunication environments, they are used to establish fast and efficient fiber backbone connections for seamless voice, video, and data transmission. Enterprises utilize MTP trunk cables to future-proof their structured cabling systems, enabling easy scalability as network demands grow. Additionally, they play a crucial role in cloud computing, AI-driven data processing, and hyperscale networking, where speed, efficiency, and reliability are critical factors.
Why Are MPO/MTP Solutions Needed In A Data Center?
As data centers continue to evolve, the demand for high-speed, high-density, and scalable network infrastructure has never been greater. Traditional fiber optic/copper cabling solutions, while effective, often struggle to keep up with the increasing bandwidth requirements, complex network architectures, and the need for space optimization. This is where MPO/MTP solutions play a critical role in modern data centers. These solutions utilize MPO (Multi-Fiber Push-On) and MTP (Multifiber Termination Push-on) technology to provide compact, high-performance fiber optic connectivity that enables seamless data transmission, reduces cabling complexity, and enhances overall network efficiency. Advantages of MPO/MTP solutions are as follows:-
High-Speed Data Transmission
Modern data centers handle enormous amounts of data traffic, requiring ultra-fast network connections. MPO/MTP solutions support high-speed data transmission standards such as 10G, 40G, 100G, 200G, and 400G, ensuring smooth and efficient data flow. As technologies like cloud computing, AI, big data, and IoT continue to expand, data centers need high-bandwidth, low-latency fiber solutions to prevent network congestion and bottlenecks. MPO/MTP trunk cables, with multiple fibers in a single connector, significantly boost data throughput per connection, making them the ideal choice for high-speed networks.
High-Density Cabling for Space Optimization
Space is a critical factor in data centers, and traditional fiber/copper cabling often leads to cable congestion. MPO/MTP solutions solve this issue by combining multiple fibers into a single, compact, and easy-to-manage cable, allowing data centers to maximize rack space and port density. This reduction in cable clutter also improves airflow, which is essential for efficient cooling and energy savings—a key factor in maintaining optimal data center operations.
Quick Deployment and Scalability
With MPO/MTP’s plug-and-play design, data centers can rapidly deploy and scale their network infrastructure without complex fiber splicing or lengthy installation processes. Pre-terminated MPO/MTP trunk cables and cassettes minimize downtime and reduce labor costs, making them perfect for fast-growing data centers that require quick and easy network expansions. This flexibility ensures that data centers can seamlessly transition from 10G to higher speeds like 40G, 100G, or 400G with minimal disruption.
Featured Products
Enhanced Reliability and Signal Integrity
Network reliability is critical for minimizing downtime and preventing financial losses. MTP connectors, an enhanced version of MPO connectors, offer low insertion loss, high return loss, and precise fiber alignment, ensuring strong, stable, and high-quality data transmission over long distances. Additionally, MPO/MTP-based systems support redundant network designs, reducing the risk of connectivity failures and improving overall system reliability.
Future-Proofing for Next-Generation Networks
With hyperscale data centers, 5G infrastructure, and evolving networking standards, MPO/MTP solutions are crucial for future-proofing data center connectivity. They provide a seamless migration path from 10G to 40G, 100G, and beyond, allowing data centers to upgrade without costly infrastructure overhauls. This adaptability makes MPO/MTP solutions a long-term, cost-effective investment for data centers looking to stay ahead in an ever-evolving digital landscape.
In summary, MPO/MTP solutions are indispensable for modern data centers, offering high-speed performance, space efficiency, fast deployment, enhanced reliability, and future scalability. By adopting MPO/MTP-based fiber optic technology, data centers can optimize network performance, reduce operational costs, and ensure seamless growth, making them a strategic and future-ready investment in high-performance IT environments.
How to Choose the Right MTP® Trunk Cable for Your Application?
Selecting the right MTP® trunk cable is essential for ensuring efficient, high-speed, and reliable fiber optic connectivity in your network infrastructure. The right choice depends on several factors, including fiber count, polarity, connector type, performance specifications, and application environment. Below are key considerations to help you choose the best MTP® trunk cable for your specific needs.
1. Determine the Fiber Count Based on Bandwidth Requirements
MTP® trunk cables are available in different fiber counts, such as 12, 24, 48, 72, and even 144 fibers. The right fiber count depends on your network's bandwidth needs:
-
12-Fiber MTP® Trunk Cables: Suitable for 10G/40G Ethernet applications.
-
24-Fiber MTP® Trunk Cables: Ideal for 100G Ethernet networks and high-speed data centers.
-
48+ Fiber MTP® Trunk Cables: Used in hyperscale data centers or ultra-high-speed environments for future scalability.
If you need a cost-effective, scalable solution, consider choosing a higher fiber count to accommodate future upgrades.
2. Choose the Right Connector Type (MTP® vs. MPO)
While both MTP® and MPO connectors are used for multi-fiber connections, MTP® connectors are an enhanced version of MPO with better performance, precision, and durability.
-
Standard MPO Connectors: General multi-fiber connections with average performance.
-
MTP® Connectors: High-performance, low-loss, and better fiber alignment for high-speed networks.
For high-density data centers and critical applications, MTP® connectors are the preferred choice due to their superior optical and mechanical performance.
3. Select the Correct Fiber Type (Single-Mode vs. Multimode)
MTP® trunk cables come in single-mode (SM) and multimode (MM) fiber types, and selecting the right one depends on your transmission distance and data rate:
-
Single-Mode (OS2): Best for long-distance transmission (10 km or more) and supports speeds of 10G, 40G, 100G, 400G+.
-
Multimode (OM3/OM4/OM5): Designed for short-range connections (up to 400m) and supports 10G, 40G, 100G, and beyond with lower cost and higher density.
For data centers and enterprise networks, OM4 or OM5 multimode cables are often used for cost-effective, short-range 40G and 100G applications, while single-mode OS2 is recommended for long-haul connections.
4. Understand Polarity Types (A, B, and C)
Polarity ensures that the transmit (Tx) and receive (Rx) signals are correctly aligned. MTP® trunk cables come in three polarity types:
-
Type A (Straight-through): Directly connects fibers from end to end (1→1, 2→2, etc.).
-
Type B (Reversed): Swaps fiber positions (1→12, 2→11, etc.), used in 40G/100G parallel optics.
-
Type C (Pair-wise Flipped): Each adjacent fiber pair is flipped (1↔2, 3↔4, etc.), mainly used in legacy duplex networks.
For modern high-speed networks, Type B polarity is preferred as it supports parallel optics and high-speed data transmission.
5. Check Performance Specifications (Standard vs. Low-Loss)
MTP® trunk cables come in different performance grades:
-
Standard Loss (Insertion Loss: ~0.75dB): Suitable for shorter runs and non-critical applications.
-
Low-Loss (Insertion Loss: ~0.35dB or lower): Recommended for high-speed, long-distance, and data center interconnects where minimal signal loss is crucial.
For 40G, 100G, and 400G applications, low-loss MTP® trunk cables provide better signal integrity and higher network efficiency.
6. Consider the Application Environment
Different environments require specific cable jackets for protection and compliance:
-
Plenum-Rated (OFNP): Used in indoor air-handling spaces to meet fire safety regulations.
-
Riser-Rated (OFNR): Suitable for vertical installations (building risers) where fire resistance is required.
-
LSZH (Low Smoke Zero Halogen): Ideal for high-density areas where minimal toxic emissions are needed.
Choosing the right cable jacket ensures compliance with safety standards and long-term durability.
7. Ensure Compatibility with Existing Infrastructure
Before purchasing an MTP® trunk cable, ensure it is compatible with your existing fiber panels, cassettes, transceivers, and networking equipment. Check:
-
Connector type (MTP®/MPO to LC, SC, etc.)
-
Fiber type (single-mode/multimode)
-
Polarity matching with patch panels and transceivers
MPO Connector Color Coding
MPO (Multi-Fiber Push-On) connector color coding is an essential industry standard that helps identify fiber types, performance grades, and polarity in high-density fiber optic networks. Proper color coding ensures seamless installation, troubleshooting, and maintenance, especially in data centers, telecom networks, and enterprise infrastructure where multiple fiber types coexist. The color of the connector housing indicates the fiber type and application, while the color of the boot or keying structure can signify polarity and performance grades.
1. MPO Connector Colors Based on Fiber Type
Different fiber types require specific MPO connectors to meet performance and compatibility standards. The connector housing color helps technicians quickly identify fiber types during installation:
-
Beige (OM1, OM2 – Multimode Fiber): Used for legacy 62.5µm (OM1) and 50µm (OM2) multimode fibers, supporting lower-speed applications like 1G and 10G Ethernet over short distances.
-
Aqua (OM3, OM4 – Laser-Optimized Multimode Fiber): Indicates 50µm multimode fibers optimized for VCSEL (Vertical Cavity Surface Emitting Laser) transmissions, supporting 40G and 100G applications over short distances.
-
Lime Green (OM5 – Wideband Multimode Fiber): Designed for short-wavelength division multiplexing (SWDM) applications, OM5 fibers extend multimode capabilities for 40G and 100G networks.
-
Blue (OS1, OS2 – Single-Mode Fiber): Identifies standard single-mode fibers (9µm core) for long-distance transmissions, typically used in telecom, metro, and backbone networks.
-
Yellow (OS2 – Low-Loss Single-Mode Fiber): Used in premium single-mode applications requiring low insertion loss, such as high-speed data centers and hyperscale environments.
2. MPO Connector Colours for Performance Grades
MPO connectors come in standard and low-loss performance variants, with low-loss connectors featuring different colour boots or markings:
-
Standard MPO Connectors: Usually have black or matching fiber colour boots, with an insertion loss of 0.75dB (multimode) or 0.35dB (single-mode).
-
Low-Loss MPO Connectors: Often have white or clear boots, designed for high-density, long-distance applications requiring minimal signal loss (0.35dB for multimode, 0.15dB for single-mode).
3. MPO Connector Keying and Polarity Color Codes
MPO connectors support Type A (Straight-through), Type B (Reversed), and Type C (Pair-Flipped) polarities, which must be matched correctly with fiber cassettes and transceivers. Some vendors use distinctive boot colors to help technicians differentiate polarity types during installations.
Deploying MTP Trunk Cables: How do you install a trunk cable?
MTP trunk cables play a critical role in high-speed data centers, enterprise networks, and telecommunication infrastructures by providing a dense, efficient, and scalable fiber optic connectivity solution. Proper installation of MTP trunk cables is essential to maximize performance, minimize signal loss, and ensure long-term network reliability. The installation process involves planning the cable route, selecting the correct polarity, ensuring proper connector alignment, and securely managing the cables within racks and panels. By following industry best practices, network engineers can optimize cable management, reduce installation time, and future-proof their infrastructure for evolving bandwidth demands.
What Are the Key Steps in MTP® Trunk Installation?
Proper installation of MTP® trunk cables is essential for ensuring high-speed, high-density, and scalable fiber optic connectivity in data centers and enterprise networks. MTP® trunk cables provide a plug-and-play solution that simplifies fiber deployments, but following structured steps during installation is crucial to achieving optimal performance, minimal signal loss, and long-term reliability. The process involves planning, cable preparation, routing, polarity management, and testing to ensure a seamless and efficient network setup. Below are the key steps to successfully install MTP® trunk cables.
Step 1: Plan the Installation Layout
Before installing MTP® trunk cables, conduct a thorough assessment of the network infrastructure to determine:
-
Cable routes and pathways (overhead trays, underfloor ducts, or vertical racks).
-
Required fiber count and cable length to avoid excessive slack or strain.
-
Polarity type (Type A, B, or C) to ensure proper signal transmission.
-
Compatibility with patch panels, cassettes, and transceivers to align with existing infrastructure.
Proper planning minimizes installation errors, improves efficiency, and ensures seamless integration with the network.
Step 2: Select the Right MTP® Trunk Cable
Choosing the correct MTP® trunk cable is critical based on:
-
Fiber Type: Single-mode (OS2) for long-distance or multimode (OM3, OM4, OM5) for short-range high-speed networks.
-
Fiber Count: 12, 24, 48, or more depending on bandwidth requirements.
-
Polarity Matching: Ensure MTP® trunks match the required A, B, or C polarity type for proper Tx/Rx alignment.
-
Performance Grade: Low-loss MTP® cables are recommended for high-speed applications like 40G/100G/400G networks.
Step 3: Install MTP® Patch Panels and Cassettes
MTP® trunk cables typically connect to fiber patch panels or cassettes, which serve as the interface between backbone cabling and end devices.
-
Securely mount MTP® cassettes or breakout panels into 19-inch racks or enclosures.
-
Ensure polarity alignment is consistent throughout the installation.
-
Label ports to simplify future maintenance and troubleshooting.
Step 4: Route and Secure MTP® Trunk Cables
Once the patch panels are in place, carefully route and secure the trunk cables to prevent stress, bending, or damage.
-
Use cable trays, ducts, or fiber organizers to ensure a structured and clutter-free deployment.
-
Maintain the minimum bend radius (typically 30mm) to prevent fiber signal degradation.
-
Secure cables using velcro ties or cable management clips—avoid over-tightening to prevent damage.
-
If deploying in raised-floor or overhead environments, ensure cables are protected from environmental hazards.
Proper cable routing and strain relief increase durability and minimize performance issues over time.
Step 5: Connect MTP® Trunk Cables to Panels and Equipment
Carefully insert MTP® connectors into the corresponding ports on fiber cassettes, patch panels, or transceivers.
-
Align the connector keying (up/down) to ensure proper insertion.
-
Apply gentle pressure to avoid damaging the connector or fiber core.
-
Use dust caps to protect unused connectors from contamination.
MTP® connectors are precision-aligned, so proper handling is crucial to maintaining high performance.
Step 6: Verify and Test the Connections
After installation, fiber testing is necessary to confirm connectivity and performance. Use the following tools:
-
Optical Power Meter (OPM): Measures signal strength and loss.
-
Optical Time-Domain Reflectometer (OTDR): Detects fiber faults, breaks, or signal reflections.
-
Visual Fault Locator (VFL): Uses red laser light to check for fiber breaks or misalignment.
-
Polarity Tester: Ensures the correct fiber routing and signal transmission.
Testing helps identify and correct issues before network activation, ensuring high reliability and efficiency.
Step 7: Document and Label the Installation
Proper documentation is key to long-term network management:
-
Label cables, ports, and patch panels for easy identification.
-
Maintain a record of fiber types, lengths, and polarity configurations.
-
Update network diagrams to reflect the installed MTP® infrastructure.
Clear documentation simplifies future expansions, troubleshooting, and upgrades.
How Do You Ensure Proper Connector Alignment and Polish?
Proper connector alignment and polish are critical for achieving optimal signal transmission, minimal insertion loss, and long-term reliability in fiber optic networks. Misaligned connectors or poor polishing can result in high signal attenuation, reflection losses, and degraded network performance. To ensure high-quality fiber optic connections, professionals follow strict alignment and polishing techniques, including precision keying, inspection, and standardized polishing procedures.
1. Ensuring Proper Connector Alignment
Connector alignment is essential to maintaining low insertion loss and high return loss. Poor alignment can lead to misfiring light signals, increased attenuation, and unreliable connections. Follow these best practices to ensure accurate alignment:
a) Use Keyed MPO/MTP® Connectors
-
MPO/MTP® connectors are designed with alignment pins and keying features to ensure precise fiber core alignment.
-
Always match male (pinned) and female (unpinned) connectors correctly to prevent misalignment.
-
Key-up to key-down (Type A) or key-up to key-up (Type B) orientations must be followed per network design.
b) Inspect Ferrule End-Faces for Contamination
-
Before connecting fibers, always inspect the ferrule end-face under a fiber inspection microscope.
-
Remove dust, dirt, and oil using lint-free wipes, fiber optic cleaning pens, or isopropyl alcohol.
-
A contaminated or scratched ferrule surface can cause signal distortion and reflection losses.
c) Avoid Excessive Force When Mating Connectors
-
Always insert connectors gently and straight into adapters or transceivers to prevent misalignment or damage.
-
Ensure connectors fully seat into the port to achieve maximum fiber-to-fiber contact.
-
Use proper polarity matching (Tx to Rx) to ensure correct data transmission.
d) Use High-Precision Alignment Sleeves
-
For LC, SC, and MPO/MTP® connectors, ceramic alignment sleeves ensure precise fiber positioning.
-
Avoid using plastic sleeves, as they can degrade over time and lead to alignment issues.
2. Best Practices for Proper Fiber Polishing
Polishing is crucial for achieving minimal insertion loss, low reflectance, and high optical performance. Different types of connectors require specific polishing techniques.
a) Select the Correct Polishing Type
Fiber connectors use different polishing profiles based on network requirements:
-
Flat Polish (PC – Physical Contact): Standard for multimode fiber but has higher return loss (~-40dB).
-
Angled Polish (APC – Angled Physical Contact, 8° angle): Used in single-mode fibers, offering superior return loss (~-60dB).
-
Ultra-Polished (UPC – Ultra Physical Contact): Provides improved return loss (~-50dB) and low insertion loss for single-mode networks.
b) Use Precision Polishing Films and Pads
-
Polishing requires diamond film pads (1µm, 3µm, 9µm) to gradually refine the fiber end-face.
-
Always use a polishing jig or fixture to maintain consistent pressure and uniform polishing.
-
Rotate the connector in a figure-eight motion to ensure an even surface finish.
c) Inspect Polished End-Faces for Quality Control
-
After polishing, inspect the fiber end-face using an interferometer or fiber microscope.
-
Ensure there are no scratches, pits, or cracks, which could increase signal loss.
-
Check that the core, cladding, and ferrule are free of contaminants and properly aligned.
d) Clean the Fiber End-Face Before Final Connection
-
Even a perfectly polished fiber must be cleaned before insertion.
-
Use dry or wet cleaning methods (lint-free wipes, cleaning pens) to remove any residual debris.
-
Avoid touching the ferrule after cleaning to maintain optimal performance.
3. Verifying Connector Alignment and Polish Performance
Once connectors are aligned and polished, testing is essential to confirm minimal signal loss and high transmission quality.
a) Optical Power Meter (OPM) Testing
-
Measures insertion loss (dB) to ensure minimal signal attenuation.
-
Compare results with acceptable loss thresholds (typically ≤0.35dB for single-mode, ≤0.75dB for multimode).
b) Optical Time-Domain Reflectometer (OTDR) Analysis
-
Detects fiber faults, misalignments, and return loss due to poor polishing or contamination.
-
Helps in diagnosing reflection spikes from improperly polished end-faces.
c) Return Loss Measurement
-
High return loss indicates proper polish and optimal signal transmission.
-
For APC connectors, return loss should be better than -60dB, while for UPC, it should be better than -50dB.
What Maintenance Practices Are Recommended For Long-Term Performance?
To ensure long-term performance and reliability of fiber optic networks, including MTP® trunk cables, regular maintenance practices must be followed. Over time, fiber optic systems can experience contamination, wear, misalignment, and signal degradation, which can impact overall network efficiency. Proper maintenance not only prevents downtime and costly repairs but also extends the lifespan of fiber components. Key maintenance practices include routine cleaning, inspection, cable management, environmental protection, and performance testing to keep the system operating at peak efficiency.
1. Regular Cleaning of Fiber Connectors and Ports
Contaminated fiber connectors are one of the leading causes of signal loss and poor network performance. Dust, dirt, and oil accumulation can obstruct light transmission, leading to increased insertion loss and return loss. To prevent contamination:
-
Use lint-free wipes, isopropyl alcohol, or fiber cleaning pens before making or reconnecting a connection.
-
Apply dry or wet cleaning methods, ensuring no residue remains on the connector end-face.
-
Store unused connectors with dust caps to prevent contamination.
-
Regularly clean patch panels, adapters, and transceivers to maintain signal integrity.
2. Routine Inspection and Testing
Periodic inspection and performance testing help detect issues before they cause network failures.
-
Use fiber inspection microscopes to check for scratches, cracks, or misalignment in fiber end-faces.
-
Conduct optical power meter (OPM) tests to measure signal strength and loss over time.
-
Perform Optical Time-Domain Reflectometer (OTDR) tests to identify fiber breaks, signal reflections, and excessive loss points.
-
Verify polarity and continuity of MTP® trunk cables to ensure proper data transmission.
3. Proper Cable Management
Poor cable management can lead to fiber stress, signal degradation, and difficult troubleshooting. Proper handling and organization of MTP® trunk cables prevent unnecessary wear and damage.
-
Maintain the minimum bend radius (typically 30mm for MTP® cables) to avoid fiber strain and breakage.
-
Use cable trays, ducts, and fiber organizers to secure cables and prevent tangling.
-
Avoid excessive pulling or twisting during installation and maintenance to prevent internal fiber misalignment.
-
Label cables, patch panels, and connections for easier identification and troubleshooting.
4. Protect Cables from Environmental Hazards
Environmental factors such as temperature fluctuations, humidity, and physical disturbances can affect fiber optic performance.
-
Keep cables away from moisture, heat sources, and high foot traffic areas.
-
Use sealed enclosures for fiber components in harsh environments.
-
Ensure proper grounding to prevent damage from electromagnetic interference (EMI) and power surges.
-
Maintain temperature-controlled environments in data centers to prevent fiber expansion and contraction.
5. Schedule Preventive Maintenance Checks
Rather than waiting for network issues to arise, scheduled preventive maintenance ensures continuous high-speed performance.
-
Implement a routine maintenance schedule to inspect fiber links, connectors, and active equipment.
-
Keep a detailed maintenance log to track performance changes, repairs, and upgrades.
-
Replace aging or damaged cables proactively before they cause failures.
What Strand Counts Should You Consider
When selecting an MTP® trunk cable, choosing the appropriate strand count (fiber count) is essential to ensure optimal network performance, scalability, and cost-effectiveness. The right fiber strand count depends on factors such as network architecture, data transmission needs, future expansion plans, and fiber optic transceiver compatibility.
Common Fiber Strand Counts in MTP® Trunk Cables
MTP® trunk cables are available in various fiber strand configurations to support different network applications. The most common strand counts include:
-
8-Fiber: Used in 40GBASE-SR4 and 100GBASE-SR4 applications with QSFP+ or QSFP28 transceivers (4 Tx + 4 Rx).
-
12-Fiber: A widely used standard for 10G to 40G migration, with options for parallel optics and breakout cabling.
-
24-Fiber: Supports 100G Ethernet (SR10) and high-density backbone connections. Efficient for spine-leaf data center designs.
-
48-Fiber and 72-Fiber: Ideal for ultra-high-density networking, hyperscale data centers, and high-speed interconnects.
-
144-Fiber and Above: Used in large-scale backbone deployments to maximize fiber density and scalability.
Conclusion
For high-speed, reliable, and scalable networking, our MTP® Trunk Cables are the superior choice. Engineered for data centers, enterprise networks, and telecom environments, these cables deliver exceptional performance, high-density connectivity, and long-term durability.
With our cutting-edge MTP® trunk cables, you ensure efficiency, scalability, and unwavering reliability—all in one solution. Enhance your network infrastructure today and achieve seamless, high-speed connectivity. Order Now and Future-Proof Your Network!